Friday, November 11, 2022

2EEC - P3196

2020 BMW 128i Coupe (E82) L6-3.0L (N51) Diagnostic Trouble Codes ( DTC ): Service instruction



none









2EEC - P3196 (DME)



2EEC - P3196







Information saved in



DME









Fault code



2EEC - P3196









Fault text



Temperature sensor cooler outlet, plausibility









Fault description



Cold Start Radiator Coolant Temperature Sensor Signal High









Condition for fault identification



Test condition:





Engine must be running





Terminal condition: Terminal 15 ON Voltage condition:





11 V < electrical system voltage < 26 V









Condition for fault memory entry



no debounce, fault code entered when engine is extremely cold (coolant temperature < -10 锟斤拷C) with excessively high sensor data reading immediately after engine start









Action in service



Visual inspection of sensor



Perform electrical check on sensor and power-supply wires



Test to determine whether the temperature really changes when the thermostat opens



Replace sensor







Fault effect and breakdown warning







Driver information



Warning light:





MIL ON in US versions only

No comments:

Post a Comment