Mercedes Benz Diagnostic and Repair Information ,Wiring Diagrams. DTC. TSB. Types: TSB, DTC, Wiring Diagrams, OEM Procedures. Trusted by more than 400,000 technicians. OEM accurate fix for faster repairs. Repair Procedures and Labor Times. Factory Auto Repair info. Request A Demo Today. Factory-Correct Diagrams. Factory Part Numbers. Maintenance Schedules. Repair Procedures. Labor Times. Types: TSB, DTC.Mercedes,Mercedes,Benz,Mercedes-Benz UK,A,Class,B,Class,C,Class,E,Class,CLA,CLS,G,Class,GLA,A
Monday, July 20, 2020
A/C - Revised Refrigerant/Compressor Oil Reuse Statement SI B 64 09 10 Heating and Air Conditioning
Technical Service Bulletin # 640910 Date: 100901
A/C - Revised Refrigerant/Compressor Oil Reuse Statement
SI B 64 09 10
Heating and Air Conditioning
September 2010
Technical Service
SUBJECT
Refrigerant and Compressor Oil Reuse
2010 BMW 328i Sedan (E90) L6-3.0L (N51) 32
MODEL
All
SITUATION
The A/C compressor test plans state "the extracted refrigerant must not be reused". This statement is incorrect.
CAUSE
Incorrect statement in the A/C compressor test plan.
INFORMATION
The extracted refrigerant can be reused. The test plan statement should read "the extracted compressor oil must not be reused". This statement will
be corrected in a future version of ISTA.
WARRANTY INFORMATION
For information only
Thursday, December 27, 2018
A/C - Revised Refrigerant/Compressor Oil Reuse Statement
view PDF attachment B640710Attachment. 2010 BMW 335Cic Convertible (E93) L6-3.0L Turbo (N54) Technical Service Bulletin # 640910 Date: 100901
A/C - Revised Refrigerant/Compressor Oil Reuse Statement
SI B 64 09 10
Heating and Air Conditioning
September 2010
Technical Service
SUBJECT
Refrigerant and Compressor Oil Reuse
MODEL
All
SITUATION
The A/C compressor test plans state "the extracted refrigerant must not be reused". This statement is incorrect.
CAUSE
Incorrect statement in the A/C compressor test plan.
INFORMATION
The extracted refrigerant can be reused. The test plan statement should read "the extracted compressor oil must not be reused". This statement will
be corrected in a future version of ISTA.