2010 Cadillac CTS Sedan AWD V6-3.6L Page 217
7. Ignition ON, test for 8.0 - 10.0 volts between the signal circuit terminal 18 and ground.
瀚慖f less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace
the windshield outside moisture sensor.
瀚慖f greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the windshield outside
moisture sensor.
8. If all circuits test normal, replace the BCM.
Repair Instructions
* Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.
* Control Module References (See: Testing and Inspection/Programming and Relearning) for BCM replacement, setup, and programming
* Windshield Outside Moisture Sensor Replacement (See: Sensors and Switches/Sensors and Switches - Wiper and Washer Systems/Rain
Sensor/Service and Repair)
B396A
DTC B396A
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System
Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an
overview of the diagnostic approach.
* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure
Instructions) provides an overview of each diagnostic category.
DTC Descriptors
DTC B396A 01
- Liftgate Motor Control Circuit Short to Battery
DTC B396A 02
- Liftgate Motor Control Circuit Short to Ground
DTC B396A 04
- Liftgate Motor Control Circuit Open
Diagnostic Fault Information
Circuit/System Description
The liftgate motor is a bi-directional motor and open or close operation is the result of the direction of the motor rotation. The liftgate control
module controls the liftgate motor through the control circuits by supplying power and ground in the appropriate polarity. The motor control
circuits are monitored by the liftgate control module prior to activation for a high or low condition and during motor operation for any irregular
current flow conditions.
Conditions for Running the DTC
* The system voltage is 9-16 volts.
* Power open or close function is initiated.
Conditions for Setting the DTC
B396A 01
The liftgate module detects a short to voltage in a liftgate motor control circuit.
No comments: