2020 BMW 128i Coupe (E82) L6-3.0L (N51) Diagnostic Trouble Codes ( DTC ): Service instruction



none









2F0D - P300B (DME)



2F0D - P300B







Information saved in



DME









Fault code



2F0D - P300B









Fault text



Radiator blind, activation, (GLF)









Fault description



Controlled Air Guiding Circuit Low









Condition for fault identification



Test condition:





AKKS must be initialized.





Terminal condition: Terminal 15 ON Voltage condition:





Voltage in onboard electrical system > 10 V









Condition for fault memory entry



up to 20 sec.









Action in service



Determine whether a possible self-diagnosis fault at the AKKS or PKKS is stored as an fault in the fault memory. (If yes, start by repairing this.)



Check wire from the DME to the AKKS



Check voltage supply at the AKKS







Fault effect and breakdown warning

Comments