Mercedes-Benz Mercedes Benz OEM Parts Mercedes Benz OE Replacement Parts
Technical Service Bulletin # LI67-30_P-0506133 Date: 120419
2010 Mercedes Benz E 550 Sedan (212.072) V8-5.5L (273.971) Page 55
Windows - Front Windows Reverse Direction When Closing
Side windows of front doors reverse direction when closing
Topic number LI67.30-P-050613
Version 3
Design group 67.30 Side windows
Date 04-19-2012
Validity A) MODEL 212 up to VIN end number A519818
B) MODEL 212 up to VIN end number A668947
Reason for change Reformatted "procedure" in Remedy Section
Complaint:
A) The side windows in the front doors may intermittently reverse direction at low outside temperatures (<<5°C) in various intermediate positions
when closing.
B) The side windows in the front doors may intermittently reverse direction when reaching the upper end position.
Cause:
The closing of the side windows has excessive resistance.
Remedy:
A.1) Replace and align side window (see WIS reference).
A.2) Replace window guide rail (see WIS reference).
B) Adapt power window parameters in left/right front DCU.
The parameters are available with add-on 2232 for XD Procedure:
1. Upload control unit log (for door specified door control module) and quick test to pSDS (paperless SDS).
2. Request password for special function "Adaptation of power window closing" via email (see below) from SDS User Help Desk.
- In email request, please include:
1. Dealer Code
2. Name
3. Phone #
4. VIN
5. Email Address
- Access Xentry Diagnosis => DCU-Fx => Adaptations => Configuration => Manual settings
=> Special functions "Adaptation of power window closing" => enter password => press "Continue" button.
Note:
Replacing the door control unit or power window motor does not remedy the problem!!
Symptoms
2010 Mercedes Benz E 550 Sedan (212.072) V8-5.5L (273.971) Page 56
Parts
Work units
WIS-References
Technical Service Bulletin # LI67-30_P-0506133 Date: 120419
2010 Mercedes Benz E 550 Sedan (212.072) V8-5.5L (273.971) Page 55
Windows - Front Windows Reverse Direction When Closing
Side windows of front doors reverse direction when closing
Topic number LI67.30-P-050613
Version 3
Design group 67.30 Side windows
Date 04-19-2012
Validity A) MODEL 212 up to VIN end number A519818
B) MODEL 212 up to VIN end number A668947
Reason for change Reformatted "procedure" in Remedy Section
Complaint:
A) The side windows in the front doors may intermittently reverse direction at low outside temperatures (<<5°C) in various intermediate positions
when closing.
B) The side windows in the front doors may intermittently reverse direction when reaching the upper end position.
Cause:
The closing of the side windows has excessive resistance.
Remedy:
A.1) Replace and align side window (see WIS reference).
A.2) Replace window guide rail (see WIS reference).
B) Adapt power window parameters in left/right front DCU.
The parameters are available with add-on 2232 for XD Procedure:
1. Upload control unit log (for door specified door control module) and quick test to pSDS (paperless SDS).
2. Request password for special function "Adaptation of power window closing" via email (see below) from SDS User Help Desk.
- In email request, please include:
1. Dealer Code
2. Name
3. Phone #
4. VIN
5. Email Address
- Access Xentry Diagnosis => DCU-Fx => Adaptations => Configuration => Manual settings
=> Special functions "Adaptation of power window closing" => enter password => press "Continue" button.
Note:
Replacing the door control unit or power window motor does not remedy the problem!!
Symptoms
2010 Mercedes Benz E 550 Sedan (212.072) V8-5.5L (273.971) Page 56
Parts
Work units
WIS-References