- Is the measurement value OK?
YES
The measurement value is OK.Further possible causes of fault
- Signal wire
- B6/7 (Right exhaust camshaft Hall sensor)
End of test
NO
The measurement value is not OK.Possible cause and remedy
- N10/1f43 (Fuse 43)
- N10/1kR (Circuit 87 relay, engine)
- Lines to component B6/7 (Right exhaust camshaft Hall sensor)
End of test
1.3. Check assignment of signals from Hall sensors 'Camshafts' and 'Crankshaft'.
Check assignment of signals from Hall sensors 'Camshafts' and 'Crankshaft'.
Figure legend
- A -ConnectionTest cable 35-pin socket box
- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Figure legend
- 1Signal from component B6/5 (Right intake camshaft Hall sensor)
- 2Signal from component B6/7 (Right exhaust camshaft Hall sensor)
- 3Signal from component B6/4 (Left intake camshaft Hall sensor)
- 4Signal from component B6/6 (Left exhaust camshaft Hall sensor)