A/T - Limp-Home Mode And DTC 0002 'Undervoltage' Stored
ESM (electronic selector lever module) fault 0002 "Undervoltage"
Topic number LI27.60-N-048766
Version 1
2010 Mercedes Benz Truck Sprinter 2500 Crew (906.733) V6-3.0L DSL Turbo (642.898) Page 96
Design group 27.60 Gearshift, control
Date 02-01-2010
Validity Sprinter model designation 906 with code G40
Reason for change Extended for MBUSA
Reason for block
Complaint:
The vehicle enters limp-home mode and has stored the fault 0002 "Undervoltage" in the ESM control module.
Cause:
The undervoltage fault is stored as an event in the ESM control module and causes the automatic transmission to enter limp-home mode.
Remedy:
Check and, if necessary, process possible causes and remedies as described in the DAS.
2010 Mercedes Benz Truck Sprinter 2500 Crew (906.733) V6-3.0L DSL Turbo (642.898)
Page 97
Load new software for the ESM control unit.