Monday, November 8, 2021

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 403


- 108 -Test cable 266 589 01 63 00



- N3/10 (ME-SFI [ME] control unit)



- II 1-63ConnectionTest cable



- III 64-126ConnectionTest cable



Warning!



- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).



Continue to test with button F2



Test sequence



- Switch off ignition.



- Connect socket box (126-pin) to component N3/10 (ME-SFI [ME] control unit).



- Measure resistance with multimeter between sockets [M.3] 3 and [F.3] 99 of the 126-pole socket box tester.



Specified value



- Resistor[11...17]ohms



Question



- Is the measurement value OK?



YES



The measurement value is OK.Note



- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose



contact and corrosion..



NO



The measurement value is not OK.Test sequence



- Switch off ignition.



- Connect shop-made test cable set to component Y62y6 (Fuel injector cylinder 6).



- Measure resistance with multimeter between pins (Y62) 1 and (Y62) 2



Specified value



- Resistor[11...13]ohms



Question



- Is the measurement value OK?

No comments:

Post a Comment