- X63/4 (CAN databus adapter connector, 2-pin)
Test sequence
- Switch off ignition.
- Measurement with multimeter
- (X63/4) 2.Measure resistance with multimeter between pins 2 and 2.1 (X63/4)
Adapter cable no. W220 589 00 99 36 may be used.Specified value
- [55...65]ohms
Question:
- Is the measured value within the specified value range?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Line from component N3/10 (ME-SFI [ME] control unit) to component X63/4 (CAN databus adapter connector, 2-pin)
- Test terminating resistor of component X63/4 (CAN databus adapter connector, 2-pin).
- Test terminating resistor of CAN element in control module N3/10 (ME-SFI [ME] control unit).
End of test
1.3.2.2.1.2. Perform measurement at component N3/10 (ME-SFI [ME] control unit).
Test total resistance of the CAN engine.
Test sequence
- Switch off ignition.
- Connect socket box to component N3/10 (ME-SFI [ME] control unit).
- Measure resistance with multimeter between sockets (F.41) 11 and (F.54) 24 of the 35-pole socket box tester.