- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Test sequence
- Switch off ignition.
- Disconnect coupling M at component N3/10 (ME-SFI [ME] control unit).
- Measure resistance with multimeter between sockets (M.75) 75 and (M.74) 74 of the 126-pole socket box tester.
Specified value
- Resistor[1...10]ohms
Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Lines between N3/10 (ME-SFI [ME] control unit) and M16/6m1 (Actuator motor)
- M16/6m1 (Actuator motor)
End of test
1.3. Perform mechanical inspection of component M16/6 (Throttle valve actuator).
Test sequence
- Switch off ignition.
- Expose component M16/6 (Throttle valve actuator).
- Slowly operate throttle flap by hand up to full load.
No comments: