Monday, February 17, 2020

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 946


- Measure direct voltage with multimeter between sockets [ F.2 ] 98 and [ F.16 ] 112 of the 35-pole socket box tester.



- Switch on ignition.



Specified value



- Voltage[11.0...15.0] V



Question



- Is the measurement value OK?



YES



The measurement value is OK.End of test



NO



The measurement value is not OK.Possible cause and remedy



- F34f42 (Fuse 42)



- Lines



End of test



2. Arrangement of fuses



Figure legend/figure



- N10/1 (Driver-side SAM control unit with fuse and relay module)



Fuses



- FuseF43-F67



Relays



- I =N10/1kI (Circuit 87 relay, engine)



- K =N10/1kK (Circuit 87 relay, chassis)



- L =N10/1kL (Starter relay)



- M =N10/1kM (SEQ [ASG] pump control relay)



- N =N10/1kN (Circuit 15 relay)



- O =N10/1kO (FAN relay module)



- P =N10/1kP (Circuit 15R relay)



- R =N10/1kR (Air pump or oil cooler fan relay)



3. Check component Y10/1 (Power steering pump pressure regulator valve).