2010 Cadillac Truck Escalade RWD V8-6.0L Hybrid Page 620
Actions Taken When the DTC Sets
The front fog lamps will not operate when the park lamps are ON and the front fog lamp switch is active.
Conditions for Clearing the DTC
* The condition responsible for setting the DTC no longer exists.
* A history DTC will clear once 100 consecutive malfunction-free ignition cycles have occurred.
Reference Information
Schematic Reference
Fog Lights Schematics (See: Diagrams/Electrical Diagrams/Lighting and Horns/System Diagram/Fog Lights Schematics)
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views)
Description and Operation
Exterior Lighting Systems Description and Operation (See: Lighting and Horns/Description and Operation/Exterior Lighting Systems Description
and Operation)
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit
Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Testing
1. Ignition OFF, disconnect the fog lamp relay.
2. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 87 and ground.
瀚慖f the test lamp illuminates, test the control circuit for a short to voltage.
3. Verify that a test lamp illuminates between the B+ circuit terminal 30 and ground.
瀚慖f the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the
B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, test or replace the fog lamp
relay.
4. Verify that a test lamp illuminates between the B+ circuit terminal 85 and ground.
瀚慖f the test lamp does not illuminate, test the B+ circuit for an open/high resistance.
5. Disconnect the harness connector at the appropriate fog lamp front.
6. Test for less than 5 ohm between the fog lamp front ground circuit terminal B and ground
瀚慖f greater than the specified range, test the ground circuit for an open/high resistance.
7. Connect the harness connector at the fog lamp front.
8. Connect a 15 A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the fog lamp front is
activated.
瀚慖f the fog lamp front does not activate and the circuit fuse is good, test the control circuit for an open/high resistance. If the circuit tests
normal, test or replace the fog lamp front.
瀚慖f the fog lamp front does not activate and the circuit fuse is open, test the control circuit for a short to ground. If the circuit tests normal,
test or replace the fog lamp front.
9. Connect a test lamp between the B+ circuit terminal 85 and the control circuit terminal 86.
10. Command the Fog Lamps ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded