the vehicle or safely contain the DC high voltage within the drive motor generator battery assembly. The 3 contactors are a positive high voltage

contactor, negative high voltage contactor, and current limit relay. These contactor/relays close and open in sequence and are controlled by the

drive motor generator battery control module. The drive motor generator battery control module monitors the control circuit voltage and 12 V

reference circuit internal to the control module to determine if the circuit is operating.

Conditions for Running the DTC

* The ignition is ON.

* The 12 V battery voltage is 9-18 V.

* The current limit relay is commanded open.

Conditions for Setting the DTC

This DTC sets when the high voltage current limit relay control circuit voltage and the drive motor generator battery control modules internal

voltage reference are within 2 V of each other when the current limit relay is commanded open.

Action Taken When the DTC Sets

* DTC P0AE7 is a type C DTC.

* After 2 failed high-voltage precharge events, a 20-40 minute precharge wait time is activated by the drive motor generator battery control

module.

Conditions for Clearing the DTC

DTC P0AE7 is a type C DTC.

Reference Information

Schematic Reference

Hybrid Energy Storage Schematics ()

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

Drive Motor Battery System Description ()

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions (See: Diagnostic Trouble Code Descriptions/Powertrain Diagnostic Trouble Code

(DTC) Type Definitions)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Special Tools

EL-48900 HEV Safety Kit

Circuit/System Verification

Verify that DTC P0AE7 is not set.

If the DTC is set, refer to High Voltage Contactor/Relay Malfunction ().

P0AE9

DTC P0A9C-P0A9E, P0AC6-P0AC8, P0ACB-P0ACD, P0AE9, P0AEA, or P0AEB

Diagnostic Instructions

Comments

Popular posts from this blog

P179D The redundancy system for DIRECT SELECT was activated. There is a signal above the permissible limit value.

P179D The redundancy system for DIRECT SELECT was activated. There is a signal above the permissible limit value.2010 Mercedes Benz E 63 AMG Sedan (212.077) V8­6.3L (156.985) Copyright ? 2013, ALLDATA 10.52SS Page 978 Possible cause: ­ A80 (Intelligent servo module for DIRECT SELECT) Affected functions: ­ Drive position selection ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ Test 1: Remedial action if control unit is faulty 'A80 (Intelligent servo module for DIRECT SELECT)' 1. Remedial action if control unit is faulty 'A80 (Intelligent servo module for DIRECT SELECT)' Operation number of operation texts and work units or standard texts and flat rates:27­0641Possible cause and remedy ­ Internal fault in control unit ­ Replace component A80 (Intelligent servo module for DIRECT SELECT). Additional measures ­ ­ Perform initial startup. Continue with button "F2" Initial startup The following procedure will guide you through all steps requ...

Dremel 4300-9/64 Versatile Corded Rotary Tool Kit with Flex Shaft and Hard Storage Case, High Power & Performance, Variable Speed- Engraver, Etcher, Sander, and Polisher, Ultimate Gift for the DIYER

  The Dremel 4300-9/64 is a versatile corded rotary tool kit designed for a wide range of applications, making it an excellent choice for DIY enthusiasts and professionals alike. Here’s an overview of its key features: ### Key Features 1. **Power and Performance**:    - **High Power Motor**: The 4300 features a powerful motor that provides efficient performance for various tasks, including engraving, etching, sanding, and polishing. 2. **Variable Speed**:    - **Adjustable RPM**: Offers a variable speed range (typically 5,000 to 35,000 RPM) for precise control, allowing you to match the speed to the material and task at hand. 3. **Flex Shaft Attachment**:    - **Enhanced Maneuverability**: The included flex shaft allows for more intricate work in tight spaces and provides a comfortable grip for detailed projects. 4. **Comprehensive Accessory Kit**:    - **Versatile Attachments**: Comes with a variety of attachments and accessories, including ...

D138, Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts

D138 The message from the auxiliary oil pump is not available on the CAN bus. Possible cause: M42 (Electric transmission oil pump) / N89 (Transmission oil additional pump control unit) Affected functions: Engine start ------------------------------------------------- Test 1: Check component M42 (Electric transmission oil pump). Check component M42 (Electric transmission oil pump). Operation number of operation texts and work units or standard texts and flat rates:27-0641Test prerequisite Battery voltage is OK. Test sequence Switch off ignition. Disconnect connector at component N89 (Transmission oil additional pump control unit). Use multimeter to check voltage directly at jacks of wiring harness for component N89 (Transmission oil additional pump control unit). Switch on ignition. Measure direct voltage with multimeter between 1 and 4Specified value - Voltage [8,5...16,4] V Question Is the measurement value OK?...