Saturday, September 21, 2019

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 227


- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).



Continue to test with button F2



Test sequence



- Measure direct current with multimeter between sockets [F.4] 100 and [M.95] 95 of the 126-pole socket box tester.



- Switch on ignition.



Testing of maximum power consumption may be conducted for no longer than 5 s.Specified value



- Amperage[1.0...1.8] A



Question



- Is the measurement value OK?



YES



The measurement value is OK.End of test



NO



The measurement value is not OK.Possible cause and remedy



- N10/1f43 (Fuse 43)



- Line from component Y49/6 (Left camshaft exhaust solenoid) to component N3/10 (ME-SFI [ME] control unit)



- Y49/6 (Left camshaft exhaust solenoid)



End of test



0073



Check potentiometer of component B37 (Accelerator pedal sensor). Hall sensor 1 : Short circuit to positive (P2123)



Possible cause:



- B37 (Accelerator pedal sensor)



Affected functions:



- Engine diagnosis



- Engine output



-------------------------------------------------

No comments: