Test sequence
- Measure direct voltage with multimeter between sockets (M.80) 80 and (M.44) 44 of the 126-pole socket box tester.
- Switch on ignition.
Specified value
- Voltage[4.8...5.3] V
Question
- Is the measurement value OK?
YES
The measurement value is OK.Possible cause and remedy
- Signal wire
- B70 (Crankshaft Hall sensor)
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Lines to component B70 (Crankshaft Hall sensor)
End of test
0120
Tooth space on sensor rotor temporarily not detected or wiring error (P0336)
Possible cause:
- B70 (Crankshaft Hall sensor)
Affected functions:
- Engine diagnosis
-------------------------------------------------
Test 1: Check component B70 (Crankshaft Hall sensor).
1. Check component B70 (Crankshaft Hall sensor).