3. ENABLE CONDITION
4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
5. DIAGNOSTIC METHOD
Abnormality Judgment
At the main IC, check the sent signal at each timing which occurs immediately after the tumble generator valve output is set to OFF -> ON,
and judge overcurrent NG when the overcurrent NG signal is sent 96 ms x 10 time(s) in a row.
Time Needed for Diagnosis: 96 ms x 10 time(s)
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgment
Judge as OK and clear the NG when the OK signal is sent.
Time Needed for Diagnosis: Less than 1 second
P2016
DTC P2016 INTAKE MANIFOLD RUNNER POSITION SENSOR / SWITCH CIRCUIT LOW (BANK 1)
1. OUTLINE OF DIAGNOSIS
Detect open or short circuit of tumble generator valve position sensor.
Judge as NG if out of specification.
2. COMPONENT DESCRIPTION