- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose
contact and corrosion..
NO
The measurement value is not OK.Test sequence
- Switch off ignition.
- Connect shop-made test cable set to component Y62y2 (Fuel injector cylinder 2).
- Measure resistance with multimeter between pins (Y62) 1 and (Y62) 2
Specified value
- Resistor[11...13]ohms
Question
- Is the measurement value OK?
YES
The measurement value is OK.Possible cause and remedy
- Lines to component Y62y2 (Fuel injector cylinder 2)
NO
The measurement value is not OK.Possible cause and remedy
- Y62y2 (Fuel injector cylinder 2)
1.1.4. Inspect component Y62y2 (Fuel injector cylinder 2) for leaks.
Figure legend
- A -ConnectionTest cable 35-pin socket box
- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2