YES
Note
- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose
contact and corrosion..
End of test
NO
The measured value is not within the specified value range.Possible cause and remedy
- Cables between component N10/1 (Driver-side SAM control unit with fuse and relay module) and control module N63/1 (DTR control
module)5A
- Cable for voltage supply
2.1.3.2.1.10. Check power supply at control unit N71 (Headlamp range adjustment control module).
If the fault code is not current, it may be deleted. In this case, the battery voltage was too low over an extended period.Charge the battery, if
necessary.Question:Is there a current undervoltage fault is several control modules?Note:This fault could result in consequential faults. You should
therefore process this fault first and then erase the fault memory.
YES
Possible cause and remedy
No comments:
Post a Comment