YES
Test prerequisite
Test sequence
- Switch on ignition.
- Unplug 4-pin connector from component N118 (Fuel pump control module).
- Measure voltage at the unclipped cable.(Ground- Positive)
- Measure direct voltage with multimeter between sockets (N118) 1.2 and (N118) 1.1
Specified values
- Voltage: [11.0 ... 14.5] V
Question
- Is the measurement value OK?
YES
The measurement value is OK.Further possible causes of fault
- Inspect plug connections for corrosion, pinched insulation and loose contact.
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Inspect lead of voltage supply to control module N118 (Fuel pump control module) if necessary for loose contact, damage and corrosion and