Mercedes Benz Truck R 320 BLUETEC Keyless Start System - Intermittent No Start, Possible DTC C426 Intermittent no start with all smart keys, ICM won't turn on

Mercedes Benz Truck R 320 BLUETEC Technical LI80-57_P-0536083 Date: 120830
Mercedes Benz Truck R 320 BLUETEC
Page 35
Keyless Start System - Intermittent No Start, Possible DTC C426
Intermittent no start with all smart keys, ICM won't turn on
Topic number LI80.57-P-053608
Version 4
Design group 80.57 Drive authorization systems (DAS)
Date 08-30-2012
Validity All W/X164 and 251 vehicles
Reason for change Further clarification of EZS fault events added
Complaint
Intermittent no start with both smart keys and the ICM will not turn on (only the multi function display will illuminate typical of a CAN wake-up).
No codes are stored in the EIS ECU. The central locking system operates normally. The guided test for the EIS and smart keys as outlined in DAS
may not reveal a fault.
Please Note:
^ If the fault cannot be verified, then monitor if there is a delay to when the ICM turns on 'after' the ignition is turned to the number 2 position.
Normally the reaction time of the ICM should be immediate.
^ Monitor if the complaint can be readily duplicated immediately after the vehicle is unlocked.
^ In the initial short test, there are no Drive Authorization codes stored in the ME control module.
^ Check the EIS ECU log and verify that there is a fault event stored as shown in the attached file (Initial EIS control unit log).
Cause
Faulty EIS
Remedy
^ Open/Close a PTSS case and attach the Initial Short Test, EIS ECU log, additional ECU logs with related drive authorization codes including
freeze frame data and the DAS test result for the EIS (see attached file: DAS_EIS_Test_Result).
^ Perform the guided DAS test in EZS and provide the test result page and a second EZS ECU log (attach these to the PTSS case as well).
Note:
Prior to performing the DAS test, you should see event code "65535" in the EZS ECU log. After performing the DAS test, this code will change to
another value such as 4, 6, 17, 25 etc. instead of 65535. This new value will be displayed on the test result page and indicates which component is
faulty (EZS, ESL; key) or if the system is okay. As per the second bullet point above, please provide both the initial EZS control unit log, and a
second log that shows the processed fault event (e.g. 4, 6, 17, etc.)
Examples of processed fault events:
Fault event 4 = Replace EZS
Fault event 6 = Replace EZS
Fault Event 17 = Replace EZS
Fault Event 25 = All is good; do not replace anything
Please Note:
Claims will be debited if the EIS is replaced for any other reason other than the criteria mentioned in this LI document, and/or the DAS data
requested is not attached to the PTSS case (see attached document for example of a drive authorization code indicating replacement of EIS).
Mercedes Benz Truck R 320 BLUETEC
Page 36
File Designation
Symptoms

Popular posts from this blog

P179D The redundancy system for DIRECT SELECT was activated. There is a signal above the permissible limit value.

P179D The redundancy system for DIRECT SELECT was activated. There is a signal above the permissible limit value.2010 Mercedes Benz E 63 AMG Sedan (212.077) V8­6.3L (156.985) Copyright ? 2013, ALLDATA 10.52SS Page 978 Possible cause: ­ A80 (Intelligent servo module for DIRECT SELECT) Affected functions: ­ Drive position selection ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ Test 1: Remedial action if control unit is faulty 'A80 (Intelligent servo module for DIRECT SELECT)' 1. Remedial action if control unit is faulty 'A80 (Intelligent servo module for DIRECT SELECT)' Operation number of operation texts and work units or standard texts and flat rates:27­0641Possible cause and remedy ­ Internal fault in control unit ­ Replace component A80 (Intelligent servo module for DIRECT SELECT). Additional measures ­ ­ Perform initial startup. Continue with button "F2" Initial startup The following procedure will guide you through all steps requ...

Dremel 4300-9/64 Versatile Corded Rotary Tool Kit with Flex Shaft and Hard Storage Case, High Power & Performance, Variable Speed- Engraver, Etcher, Sander, and Polisher, Ultimate Gift for the DIYER

  The Dremel 4300-9/64 is a versatile corded rotary tool kit designed for a wide range of applications, making it an excellent choice for DIY enthusiasts and professionals alike. Here’s an overview of its key features: ### Key Features 1. **Power and Performance**:    - **High Power Motor**: The 4300 features a powerful motor that provides efficient performance for various tasks, including engraving, etching, sanding, and polishing. 2. **Variable Speed**:    - **Adjustable RPM**: Offers a variable speed range (typically 5,000 to 35,000 RPM) for precise control, allowing you to match the speed to the material and task at hand. 3. **Flex Shaft Attachment**:    - **Enhanced Maneuverability**: The included flex shaft allows for more intricate work in tight spaces and provides a comfortable grip for detailed projects. 4. **Comprehensive Accessory Kit**:    - **Versatile Attachments**: Comes with a variety of attachments and accessories, including ...

D138, Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts

D138 The message from the auxiliary oil pump is not available on the CAN bus. Possible cause: M42 (Electric transmission oil pump) / N89 (Transmission oil additional pump control unit) Affected functions: Engine start ------------------------------------------------- Test 1: Check component M42 (Electric transmission oil pump). Check component M42 (Electric transmission oil pump). Operation number of operation texts and work units or standard texts and flat rates:27-0641Test prerequisite Battery voltage is OK. Test sequence Switch off ignition. Disconnect connector at component N89 (Transmission oil additional pump control unit). Use multimeter to check voltage directly at jacks of wiring harness for component N89 (Transmission oil additional pump control unit). Switch on ignition. Measure direct voltage with multimeter between 1 and 4Specified value - Voltage [8,5...16,4] V Question Is the measurement value OK?...