YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Line from component N10/1 (Front SAM control unit with fuse and relay module) to component N15/6 (Sprintshift control module)
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Check fuse "f63" (voltage supply from control unit ASG) in component N10/1 (Front SAM control unit with fuse and relay module).
- Test cables
End of test
1.1.3.2.1.7. Check power supply at control unit N47-5 (ESP, SPS [PML] and BAS control unit).
Test 1.1.3.2.1.7.1: Test voltage of terminal 87 at control unit N47-5 (ESP, SPS [PML] and BAS control unit).
Test 1.1.3.2.1.7.2: Test of cable for voltage supply
Test 1.1.3.2.1.7.3: Test procedure ground cable
1.1.3.2.1.7.1. Test voltage of terminal 87 at control unit N47-5 (ESP, SPS [PML] and BAS control unit).
Test prerequisite
- Battery voltage is OK.
Test sequence
- Switch off ignition.
- Connect socket box.
- Switch on ignition.
- Measure direct voltage with multimeter between sockets (2.23) 57 and (2.14) 48 of the 126-pole socket box tester.
Specified value
- [11...14 V]
Question
- Is the measurement value OK?
No comments: