Wednesday, August 21, 2019

2A44 - P1062

2020 BMW 128i Coupe (E82) L6-3.0L (N51) Diagnostic Trouble Codes ( DTC ): Service instruction



none









2A44



2A44 - P1062







Information saved in



DME









Fault code



2A44 - P1062









Fault text



Valvetronic, power limitation









Fault description



VVT-Limp Home Request Full Stroke Position not Reached (Bank 1)









Condition for fault identification



Test condition:





VVT must be in emergency operation mode (meaning that no VVT sensor signal is present) and unit travels to upper travel limit at 30 % pulse-duty factor for VVT motor.



The mass induction airflow is employed as an index to determine whether the maximum VVT stroke has been reached.



Terminal condition: Terminal 15 ON Voltage condition:





none









Condition for fault memory entry



after Terminal 15 switch and/or always active if DME is awake.









Action in service



Check and repair the sensor defect using the correct repair instructions.



Check HFM mass airflow signal



2. Check VVT mechnical system (VVT servo motor, VVT gearset, VVT eccentric shaft,...)









Fault effect and breakdown warning







Driver information



Warning light:





ECE: No warning message. Engine reverts to VVT emergency backup mode (throttled operation) US: OPEN

No comments: