- Process displayed fault codes in control module Engine management.
END OF TEST
2768
Component Y3/8n2 (Internal speed sensor (VGS)) is defective.
Possible cause:
- Y3/8n2 (Internal speed sensor (VGS))
Affected functions:
- Automatic transmission Function
-------------------------------------------------
Test 1: Remedial action if component 'Y3/8n2 (Internal speed sensor (VGS))' is faulty
1. Remedial action if component 'Y3/8n2 (Internal speed sensor (VGS))' is faulty
Warning!Communication with ECU required.
2805
The signals of the range selector sensor are implausible in comparison to the signals from the electronic selector lever module.
Possible cause:
- Y3/8s1 (Selection range sensor (VGS))
Affected functions:
- Automatic transmission Function
-------------------------------------------------
Test 1: Remedial action after a plausibility error between the signals from components Y3/8s1 (Selection range sensor (VGS)) and N15/5
(Electronic selector lever module control unit)
1. Remedial action after a plausibility error between the signals from components Y3/8s1 (Selection range sensor (VGS)) and N15/5
(Electronic selector lever module control unit)
Operation number of operation texts and work units or standard texts and flat rates:27-0641Cause
- The shift rod is not adjusted correctly.
REMEDY
- Adjust the shift rod as per the repair instructions.
WARNING
- This is not a function error in system 'ETC' and does not justify exchanging components.
- If the complaint occurs repeatedly contact your workshop support.
End of test
2810
The internal electrical check of component Y3/8y1 (Working pressure control solenoid valve (VGS)) has failed.
Possible cause:
- Y3/8y1 (Working pressure control solenoid valve (VGS))
Affected functions:
- Automatic transmission Function
-------------------------------------------------
No comments: