Thursday, August 1, 2019

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 1715


3.1.3.2.1.12. Check power supply at control unit A89 (DTR controller unit).



Check power supply at control unit A89 (DTR controller unit).



Figure legend



- A89 (DTR controller unit)



Test prerequisite



- The voltage test at component G1 (Battery) is o.k.



- Fuse 45 in component N10/1 (Driver-side SAM control unit with fuse and relay module) is o.k.



Test sequence



- Switch off ignition.



- Detach coupling at component A89 (DTR controller unit).



- 1.Measure direct voltage with multimeter between sockets 1 and 1.6



- Switch on ignition.



Specified value



- [11.0 ... 14.5] V



Question



- Is the value o.k.?



YES



Note



- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose



contact and corrosion..

No comments:

Post a Comment