Wednesday, July 24, 2019

2020 Subaru Forester P code Page 206

Normality Judgment

Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.

Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms

Overflow diagnosis

Perform secondary air system flow abnormality diagnosis using both sides of combination valves secondary air amount when both are closed.

Judge as secondary air system flow abnormality either if there is excessive secondary air flow amount with the RH combination valve closed,

or if there is excessive secondary air flow amount with the LH combination valve closed.

Abnormality Judgment

If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.

Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms

Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.

Normality Judgment

Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.

Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms

No comments:

Post a Comment