1.1.3.2.1.7. Check power supply at control unit A89 (DTR controller unit).
Check power supply at control unit A89 (DTR controller unit).
Figure legend
- A89 (DTR controller unit)
Test prerequisite
- The voltage test at component G1 (Battery) is o.k.
- Fuse 45 in component N10/1 (Driver-side SAM control unit with fuse and relay module) is o.k.
Test sequence
- Switch off ignition.
- Detach coupling at component A89 (DTR controller unit).
- 1.Measure direct voltage with multimeter between sockets 1 and 1.6
- Switch on ignition.
Specified value
- [11.0 ... 14.5] V
Question
- Is the value o.k.?
YES
Note
- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose
contact and corrosion..
No comments: