2010 Cadillac Truck SRX FWD V6-3.0L Page 1619
P0625
The ECM detects a pulse width modulated (PWM) signal less than 5% for 15 s.
P0626
The ECM detects a pulse width modulated (PWM) signal greater than 65% for 15 s.
Action Taken When the DTC Sets
DTC P0625 and P0626 are C type DTCs.
Conditions for Clearing the DTC
DTC P0625 and P0626 are C type DTCs.
Reference Information
Schematic Reference
Starting and Charging Schematics (See: Starting and Charging/Diagrams/Electrical Diagrams)
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views/Connector End Views By Name)
Description and Operation
Charging System Description and Operation (See: Starting and Charging/Charging System/Description and Operation)
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit
Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions (See: Diagnostic Trouble Code Descriptions/Powertrain Diagnostic Trouble Code
(DTC) Type Definitions)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Verification
Engine running, observe the scan tool Generator F-Terminal Signal Circuit parameter. The Generator F-Terminal Signal Circuit parameter should
display between 5-99%.
Circuit/System Testing
1. Verify that a test lamp illuminates between the G13 Generator B+ terminal A X1 and ground.
瀚慖f the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
2. Ignition OFF, disconnect the X2 harness connector at the G13 Generator.
3. Ignition ON, verify the scan tool Generator F-Terminal Signal parameter displays less than 5%.
瀚慖f greater than the specified range, test the signal circuit terminal 2 for a short to voltage. If the circuit tests normal, replace the K20
Engine Control Module.
4. Install a 3 A fused jumper wire between B+ and the signal circuit terminal 2.
5. Verify the scan tool Generator F-Terminal Signal parameter displays greater than 95%.
瀚慖f less than the specified range, test the signal circuit terminal 2 for a short to ground or an open/high resistance. If the circuit tests
normal, replace the K20 Engine Control Module.
6. If the circuit tests normal replace the G13 Generator.
No comments:
Post a Comment