Tuesday, September 7, 2021

2010 Cadillac Truck SRX FWD V6-3.0L Page 314

2010 Cadillac Truck SRX FWD V6-3.0L Page 314



* The engine is running.



* Headlamp switch in AUTO position.



* The ambient light is day.



Conditions for Setting the DTC



B260D 01 or B260E 01



The BCM detects a short to voltage on the daytime running lamp control circuit



B260D 02 or B260E 02



The BCM detects a short to ground on the daytime running lamp control circuit



B260D 04 or B260E 04



The BCM detects an open/high resistance on the daytime running lamp control circuit



Action Taken When the DTC Sets



B260D 01 or B260E 01



The daytime running lamp will be continuously illuminated.



B260D 02, B260D 04, B260E 02 or B260E 04



The daytime running lamp will be inoperative



Conditions for Clearing the DTC



* The DTC will be current for as long as the fault is present.



* When the fault is no longer present, the DTC will be a history DTC.



* A history DTC will clear after 50 ignition cycles.



Reference Information



Schematic Reference



Exterior Lights Schematics (See: Diagrams/Electrical Diagrams/Lighting and Horns/System Diagram/Exterior Lights Schematics)



Connector End View Reference



Component Connector End Views (See: Diagrams/Connector Views/Connector End Views By Name)



Description and Operation



Exterior Lighting Systems Description and Operation (See: Lighting and Horns/Description and Operation/Exterior Lighting Systems)



Electrical Information Reference



* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit



Testing/Circuit Testing)



* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic



Procedures/Connector Repairs/Connector Repairs)



* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General



Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring



Repairs/Wiring Repairs)



Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning)



Circuit/System Verification



Ignition ON, command the Left Dedicated Daytime Running Lamp and the Right Dedicated Daytime Running Lamp ON and OFF with a scan tool.



The E4C daytime running lamp - left and the E4D daytime running lamp - right should turn ON and OFF while changing between the commanded



states.



Circuit/System Testing



1. Ignition OFF, disconnect the X1 harness connector K9 BCM.



2. Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 3 and ground.

No comments:

Post a Comment