Monday, July 26, 2021

2010 Cadillac Truck SRX FWD V6-3.0L Page 366

2010 Cadillac Truck SRX FWD V6-3.0L Page 366



1. Ignition OFF, disconnect the harness connector at the S45B liftgate control switch-interior.



2. Test for the values listed below between the signal terminal 3 and the ground terminal 1.



* 600-650 ohm in the Off position



* 125k-140k ohm in the 3/4 position



* 400k-415k ohm in the Max position



瀚慖f not within the specified ranges, replace the S45B liftgate control switch-interior.



3. Test for infinite resistance between the signal terminal 4 and the ground terminal 1 with the switch open.



瀚慖f not the specified value, replace the S45B liftgate control switch-interior.



4. Test for less than 3 ohm between the signal terminal 4 and the ground terminal 1 with the switch closed.



瀚慖f greater than the specified range, replace the S45B liftgate control switch-interior.



Repair Instructions



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the repair.



* Liftgate Actuator Control Switch Replacement (See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Trunk / Liftgate



Motor/Service and Repair)



* Control Module References (See: Testing and Inspection/Programming and Relearning) for the liftgate control module replacement, setup



and programming



B396E



Liftgate Close Switch Malfunction - DTC B396E



Diagnostic Instructions



* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System



Check - Vehicle) prior to using this diagnostic procedure.



* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an



overview of the diagnostic approach.



* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure



Instructions) provides an overview of each diagnostic category.



DTC Descriptor



DTC B396E 02



- Rear Liftgate Actuator Switch Circuit Short To Ground



Diagnostic Fault Information



Circuit/System Description



The liftgate close switch circuit provides a single input to the liftgate control module. The liftgate close switch is supplied a signal voltage, when



the switch contact closes, the liftgate control module detects the voltage drop and commands the liftgate to close.



Conditions for Running the DTC



The system voltage is 9-16 V.



Conditions for Setting the DTC



The liftgate control module detects the liftgate close signal circuit is active for greater than 30 seconds.



Action Taken When the DTC Sets



The liftgate control module will ignore the input from the liftgate close switch, the liftgate will only power close by using the interior liftgate

No comments: