Monday, May 3, 2021

2010 Cadillac Truck SRX FWD V6-3.0L Page 365

2010 Cadillac Truck SRX FWD V6-3.0L Page 365



Electrical Information Reference



* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General



Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)



* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit



Testing/Circuit Testing)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring



Repairs/Wiring Repairs)



* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic



Procedures/Connector Repairs/Connector Repairs)



Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information



Circuit/System Verification



1. Ignition ON, verify the scan tool Liftgate Mode Switch parameter changes from 125 counts to 350 counts to 245 counts while rotating the



S45B liftgate control switch - interior.



瀚慖f the value does not change with each position selected, refer to OFF/ 3/4 position/MAX Switch Circuit Test



2. Place the S45B liftgate control switch - interior to the OFF position.



3. Observe the scan tool Liftgate Front Control Switch parameter while pressing and releasing the liftgate button on the S45B liftgate control



switch-interior. The parameter should change between Inactive and Active.



瀚慖f the value does not change, refer to Open/Close Switch Circuit Test



Circuit/System Testing



OFF/ 3/4 position/MAX Switch Circuit Test



1. Ignition OFF, disconnect the harness connector at the S45B liftgate control switch-interior.



2. Test for less than 10 ohm between the ground circuit terminal 1 and ground.



瀚慖f greater than the specified range, test the ground circuit for a open/high resistance.



3. Ignition ON, verify the scan tool Liftgate Mode Switch parameter is greater than 300 counts.



瀚慖f less than the specified range, test the signal circuit terminal 3 for a short to ground. If the circuit tests normal, replace the K39 liftgate



module.



4. Install a 3A fused jumper wire between the signal circuit terminal 3 and ground, verify the scan tool Liftgate Mode Switch parameter is less



than 5 counts.



瀚慖f greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal,



replace the K39 liftgate module.



5. If all circuits test normal, test or replace the S45B liftgate control switch-interior.



Open/Close Switch Circuit Test



1. Ignition OFF, disconnect the harness connector at the S45B liftgate control switch-interior.



2. Test for less than 10 ohm between the ground circuit terminal 1 and ground.



瀚慖f greater than the specified range, test the ground circuit for a open/high resistance.



3. Ignition ON, verify the scan tool Liftgate Front Control Switch parameter is Inactive.



瀚慖f not the specified value, test the signal circuit terminal 4 for a short to ground. If the circuit tests normal, replace the K39 liftgate control



module.



4. Install a 3 A fused jumper wire between the signal circuit terminal 4 and ground. Verify the scan tool Liftgate Front Control Switch



parameter is Active.



瀚慖f not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the



K39 liftgate control module.



5. If all circuits test normal, test or replace the S45B liftgate control switch-interior.