Thursday, May 13, 2021

2010 Cadillac Truck SRX FWD V6-3.0L Page 480

2010 Cadillac Truck SRX FWD V6-3.0L Page 480



Circuit/System Description



The keyless entry control module supplies a 12V signal to the left rear and right rear exterior door handle switches. When the door handle is



activated, the switch closes and the voltage signal from the keyless entry control module are pulled to ground, this input allows the keyless entry



control module to detect a door open request.



Conditions for Running the DTC



Battery voltage is between 9-16 V.



Conditions for Setting the DTC



B1534 02



The keyless entry control module detects the left rear exterior door handle switch signal circuit is shorted to ground or closed for greater than 60



seconds.



B1535 02



The keyless entry control module detects the right rear exterior door handle switch signal circuit is shorted to ground or closed for greater than 60



seconds.



Action Taken When the DTC Sets



B1534 02



The passive entry feature will be inoperative for the left rear door and the left rear door will not open unless the door is first unlocked by pressing



the appropriate button on the keyless entry transmitter.



B1535 02



The passive entry feature will be inoperative for the right rear door and the right rear door will not open unless the door is first unlocked by



pressing the appropriate button on the keyless entry transmitter.



Conditions for Clearing the DTC



* The DTC will be current for as long as the fault is present.



* When the fault is no longer present, the DTC will be a history DTC.



* A history DTC will clear after 50 ignition cycles.



Reference Information



Schematic Reference



Door Lock/Indicator Schematics (See: Body and Frame/Locks/Diagrams/Electrical Diagrams/Door Lock/Indicator Schematics)



Connector End View Reference



Component Connector End Views (See: Diagrams/Connector Views/Connector End Views By Name)



Description and Operation



Power Door Locks Description and Operation (See: Body and Frame/Locks/Power Locks/Description and Operation)



Electrical Information Reference



* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit



Testing/Circuit Testing)



* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic



Procedures/Connector Repairs/Connector Repairs)



* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General



Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring



Repairs/Wiring Repairs)