Tuesday, March 30, 2021

2010 Cadillac Truck SRX FWD V6-3.0L Page 746

2010 Cadillac Truck SRX FWD V6-3.0L Page 746



* The DTC will be current for as long as the fault is present.



* When the fault is no longer present, the DTC will be a history DTC.



* A history DTC will clear after 50 ignition cycles.



Reference Information



Schematic Reference



Exterior Lights Schematics (See: Diagrams/Electrical Diagrams/Lighting and Horns/System Diagram/Exterior Lights Schematics)



Connector End View Reference



Component Connector End Views (See: Diagrams/Connector Views/Connector End Views By Name)



Description and Operation



Exterior Lighting Systems Description and Operation (See: Lighting and Horns/Description and Operation/Exterior Lighting Systems)



Electrical Information Reference



* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit



Testing/Circuit Testing)



* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic



Procedures/Connector Repairs/Connector Repairs)



* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General



Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring



Repairs/Wiring Repairs)



Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information



Circuit/System Verification



1. Ignition ON, with the turn signal switch in the left position, observe the function of the E4LF turn signal lamp-left front and the E4Y turn



signal repeater lamp-left. Each lamp should flash ON and OFF.



2. With the turn signal switch in the right position, observe the function of the E4RF turn signal lamp-right front and the E4Z turn signal



repeater lamp-right. Each lamp should flash ON and OFF.



Circuit/System Testing



1. Ignition OFF, disconnect the harness connector at the appropriate turn signal lamp.



2. Test for less than 30 ohm between the ground circuit terminal listed below and ground.



* E4Y turn signal repeater lamp-left terminal 2



* E4Z turn signal repeater lamp-right terminal 2



瀚慖f greater than the specified range, test the ground circuit for an open/high resistance.



3. Disconnect the inline harness connector at the appropriate E4LF turn signal lamp-front listed below:



* E4LF turn signal lamp-left front X115 (Without TT6/TT7/TT8)



* E4LF turn signal lamp-left front X111 (With TT6/TT7/TT8)



* E4RF turn signal lamp-right front X116 (Without TT6/TT7/TT8)



* E4RF turn signal lamp-right front X112 (With TT6/TT7/TT8)



4. Connect a test lamp between the control circuit terminal listed below and ground.



* E4LF turn signal lamp-left front terminal J



* E4RF turn signal lamp-right front terminal J



* E4Y turn signal repeater lamp-left terminal 1



* E4Z turn signal repeater lamp-right terminal 1



5. Command the appropriate Turn Signal Lamp ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between



the commanded states.



瀚慖f the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the K9 BCM.



瀚慖f the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace



the K9 BCM.



6. If all circuits test normal, replace the turn signal lamp.