Wednesday, March 10, 2021

2010 Cadillac Truck SRX AWD V6-3.0L Page 2028

2010 Cadillac Truck SRX AWD V6-3.0L Page 2028



P2270



DTC P2270 or P2272 (LF1)



Diagnostic Instructions



* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System



Check - Vehicle) prior to using this diagnostic procedure.



* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an



overview of the diagnostic approach.



* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure



Instructions) provides an overview of each diagnostic category.



DTC Descriptors



DTC P2270



- HO2S Signal Stuck Lean Bank 1 Sensor 2



DTC P2272



- HO2S Signal Stuck Lean Bank 2 Sensor 2



Diagnostic Fault Information



Typical Scan Tool Data



Circuit/System Description



The heated oxygen sensors (HO2S) are used for fuel control and catalyst monitoring. Each HO2S compares the oxygen content of the surrounding



air with the oxygen content of the exhaust stream. When the engine is started, the control module operates in an Open Loop mode, ignoring the



HO2S signal voltage while calculating the air-to-fuel ratio. While the engine runs, the HO2S heats up and begins to generate a voltage within a



range of 0-1,275 mV. Once sufficient HO2S voltage fluctuation is observed by the control module, Closed Loop is entered. The control module



uses the HO2S voltage to determine the air-to-fuel ratio. An HO2S voltage that increases toward 1,000 mV indicates a rich fuel mixture. An HO2S



voltage that decreases toward 0 mV indicates a lean fuel mixture.