2010 Cadillac Truck SRX AWD V6-3.0L Page 664
* The affected stepper motor is deactivated.
Conditions for Clearing the DTC
The condition for setting the DTC is no longer present.
Reference Information
Schematic Reference
HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams)
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views/Connector End Views By Name)
Description and Operation
Automatic HVAC Description and Operation (See: Heating and Air Conditioning/Description and Operation)
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit
Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Verification
1. Verify that DTC B023A 02 is not present.
瀚慖f DTC is present, refer to Actuator Power Supply Malfunction.
2. Verify that DTC B0223, B022A, B0233, B0408 or B0418 is not set.
瀚慖f DTC is present, refer to Actuator Malfunction.
Circuit/System Testing
Actuator Power Supply Malfunction
1. Ignition OFF, disconnect the harness connector at the appropriate actuator.
2. Ignition ON, verify that a test lamp illuminates between the 12 volt referance circuit terminal 2 and ground.
瀚慖f the test lamp does not illuminate, test the 12 volt referance circuit for a short to ground or an open/high resistance. If the circuit tests
normal test or replace the K33 HVAC control module.
Actuator Malfunction
1. Ignition OFF, disconnect the X3 and X4 harness connector at the K33 HVAC Control Module.
2. Ignition ON, test for 80-200 ohm between the 12 V reference voltage circuit terminal 15 X3 and each control circuit terminal of the
appropriate actuator.
瀚慖f less than the specified range, test for the 12 V reference voltage circuit and the control circuit for a short circuit. If the circuits test
normal, replace the appropriate actuator.
瀚慖f greater than the specified range, test the 12 V reference voltage circuit and the control circuit for an open/high resistance. If the circuits
test normal, replace the appropriate actuator.
3. If all circuits test normal, replace the K33 HVAC Control Module
Repair Instructions
Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.
* HVAC Component Replacement Reference (See: Heating and Air Conditioning/Service and Repair/Removal and Replacement)
* Control Module References (See: Testing and Inspection/Programming and Relearning) for HVAC control module replacement, setup, and