Thursday, August 27, 2020

2010 Cadillac Truck Escalade/ESV RWD V8-6.2L Page 284

2010 Cadillac Truck Escalade/ESV RWD V8-6.2L Page 284

* The system will operate as if no sunload condition exists.

Conditions for Clearing the DTC

* The DTC will become history if the HVAC control module no longer detects the condition that set the DTC.

* The history DTC will clear after 100 fault-free ignition cycles.

Reference Information

Schematic Reference

HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams/HVAC - Automatic)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

* Air Temperature Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air

Temperature Description and Operation)

* Air Delivery Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air Delivery

Description and Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Circuit/System Verification

Ignition ON, observe the appropriate scan tool Sunload Sensor parameter. The reading should be between 5 and 250 counts and change with

sunlight intensity.

Circuit/System Testing

Important: If a solar load sensor has an out of range condition caused by a short to voltage, short to ground, or an open/high resistance,

the scan tool will display the same value: 225 counts.

1. Ignition OFF, disconnect the harness connector at the sunload sensor.

2. Test for less than 10 ohms between the ground circuit terminal C and ground.

瀚慖f greater than the specified range, test the ground circuit for an open/high resistance.

3. Ignition ON, test for 4.8-5.2 volts between the ground circuit terminal C and the appropriate signal circuit terminal listed below:

* Left solar load sensor circuit terminal A.

* Right solar load sensor circuit terminal B.

瀚慖f less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the

HVAC control module.

瀚慖f greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control

module.

4. If all circuits test normal, test or replace the sunload sensor.

Repair Instructions

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.

* Ambient Light Sensor Replacement (See: Lighting and Horns/Ambient Light Sensor/Service and Repair)

* Control Module References (See: Testing and Inspection/Programming and Relearning) for HVAC control module replacement, setup, and

No comments:

Post a Comment