2010 Cadillac Truck Escalade/ESV RWD V8-6.2L Page 356
Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Verification
Clear all DTCs and operate the integrated switches at each door control module within the Conditions for Running the DTC. The DTC should not
set.
If the DTC sets, replace the appropriate door switch.
Repair Instructions
Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.
Control Module References (See: Testing and Inspection/Programming and Relearning) for DDS and PDS replacement, setup, and programming
HVAC - Automatic
DTC B1023
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System
Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an
overview of the diagnostic approach.
* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure
Instructions) provides an overview of each diagnostic category.
DTC Descriptor
DTC B1023 05
- Integral Switch Performance Short to Ground
DTC B1023 06
- Integral Switch Performance Short to Battery or Open
DTC B1023 61
- Integral Switch Performance Signal Invalid
Circuit/System Description
This DTC is not associated with any wiring. It is an internal fault inside the HVAC control module for a stuck or shorted control button.
Conditions for Running the DTC
Battery voltage is between 9-16 volts and data link communications operate normally.
Conditions for Setting the DTC
The HVAC control module has internal fault inside the HVAC control module for a stuck or shorted control button.
Conditions for Clearing the DTC
* A current DTC clears when the malfunction is no longer present.
* A history DTC clears when the module ignition cycle counter reaches the reset threshold, without a repeat of the malfunction.
Circuit/System Verification
1. Reprogram the HVAC control module that set DTC B1023. The module should successfully reprogram.