2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 2750


- Measure direct voltage with multimeter between ground socket and socket



Specified value



- Voltage[11.0...14.5] V



Question



- Is the measurement value OK?



( Picture : Example )



YES



Test sequence



- Unplug connector 8 at control unit N93 (Central gateway control unit).



- Measurement at connector 8



- Measure direct voltage with multimeter between sockets (N93) 8.1 and (N93) 8.6



Specified value



- Voltage[11.0...14.5] V



Question



- Is the measurement value OK?



YES



The measurement value is OK.Restore original status.



- Plug in the connector 8 at component N93 (Central gateway control unit).

Comments