transmission control module temperature. This temperature reading is used in various shifting and diagnostic routines in the transmission control
module software.
Conditions for Running the DTC
* Ignition voltage is 11-18 V.
* The engine speed is greater than 450 RPM.
* No DTCs P0722 or P0723.
P0667
* No DTCs P0711, P0712, P077B, or P215C.
* DTC P0667 has not passed this key ON.
* The transmission control module temperature is between -39 and +149掳C (-38 and +300掳F).
P0668
DTC P0668 has not failed this ignition cycle.
P0669
* The transmission OSS parameter is greater than 200 RPM for greater than 200 seconds.
* DTC P0669 has not failed this ignition cycle.
Conditions for Setting the DTC
P0667 - Fail Case 1
* Vehicle speed is greater than 8 km/h (5 mph) for 200 seconds cumulative.
* The TCM Temperature parameter is between -50 and +21掳C (-58 and +70掳F).
* The TCM Temperature parameter has changed by less than 2.0掳C (3.6掳F) in 100 seconds.
* The Trans. Fluid Temp. parameter is greater than 70掳C (158掳F).
* The TFT has increased by 55掳C (99掳F) since startup.
P0667 - Fail Case 2
* Vehicle speed is greater than 8 km/h (5 mph) for 200 seconds cumulative.
* The TCM temperature parameter is between 120-150掳C (248-302掳F).
* The TCM temperature parameter has changed by less than 2.0掳C (3.6掳F) in 100 seconds.
* The Trans. Fluid Temp. parameter is greater than 70掳C (158掳F).
* The Trans. Fluid Temp. parameter has increased by 55掳C (99掳F) since startup.
P0667 - Fail Case 3
The TCM temperature parameter changes by greater than or equal to 20掳C (36掳F) 14 times over 7 seconds.
P0668
The TCM temperature is parameter greater than or equal to 161掳C (321掳F) for greater than 10 seconds.
P0669
The TCM temperature parameter is less than or equal to -61掳C (-77掳F) for greater than 10 seconds.
Action Taken When the DTC Sets
DTCs P0667, P0668, and P0669 are Type B DTCs.
Conditions for Clearing the DTC
DTCs P0667, P0668, and P0669 are Type B DTCs.
Diagnostic Aids
This DTC may be set due to an overheating condition. The system is operating normally when the Trans. Fluid Temp. parameter is within 10掳C (18