2010 Cadillac Truck Escalade RWD V8-6.0L Hybrid Page 283
* The system will operate as if no sunload condition exists.
Conditions for Clearing the DTC
* The DTC will become history if the HVAC control module no longer detects the condition that set the DTC.
* The history DTC will clear after 100 fault-free ignition cycles.
Reference Information
Schematic Reference
HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams/HVAC - Automatic)
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views)
Description and Operation
* Air Temperature Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air
Temperature Description and Operation)
* Air Delivery Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air Delivery
Description and Operation)
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit
Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Verification
Ignition ON, observe the appropriate scan tool Sunload Sensor parameter. The reading should be between 5 and 250 counts and change with
sunlight intensity.
Circuit/System Testing
Important: If a solar load sensor has an out of range condition caused by a short to voltage, short to ground, or an open/high resistance,
the scan tool will display the same value: 225 counts.
1. Ignition OFF, disconnect the harness connector at the sunload sensor.
2. Test for less than 10 ohms between the ground circuit terminal C and ground.
瀚慖f greater than the specified range, test the ground circuit for an open/high resistance.
3. Ignition ON, test for 4.8-5.2 volts between the ground circuit terminal C and the appropriate signal circuit terminal listed below:
* Left solar load sensor circuit terminal A.
* Right solar load sensor circuit terminal B.
瀚慖f less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the
HVAC control module.
瀚慖f greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control
module.
4. If all circuits test normal, test or replace the sunload sensor.
Repair Instructions
Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.
* Ambient Light Sensor Replacement (See: Lighting and Horns/Ambient Light Sensor/Service and Repair)
* Control Module References (See: Testing and Inspection/Programming and Relearning) for HVAC control module replacement, setup, and
No comments:
Post a Comment