2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 1149
DTC P0ADC
- Hybrid Battery Positive Contactor Control Circuit High Voltage
Diagnostic Fault Information
Circuit/System Description
The drive motor generator battery control module is also referred to as the battery energy control module (BECM). The drive motor generator
battery control module will diagnose its own systems and determine when a fault condition is present. Diagnostics and system status is
communicated from the drive motor generator battery control module to the hybrid powertrain control module (HPCM) through serial data. The
hybrid powertrain control module is the host controller for diagnostic trouble code (DTC) information.
The hybrid drive motor generator battery contains 3 high voltage contactors. The contactors allow the high voltage DC batteries to be connected to
the vehicle or safely contain the DC high voltage within the drive motor generator battery assembly. The 3 contactors are a positive high voltage
contactor, negative high voltage contactor, and current limit relay. These contactor/relays close and open in sequence and are controlled by the
drive motor generator battery control module. The drive motor generator battery control module monitors the control circuit voltage and 12 V
reference circuit internal to the control module to determine if the circuit is operating.
Conditions for Running the DTC
P0ADB
* The ignition is ON.
* The jump assist function is not active.
* The 12 V battery voltage is 9-18 V.
* High voltage contactors are commanded closed.
P0ADC
* The 12 V battery voltage is 9-18 V.
* High voltage contactors are commanded open.
Conditions for Setting the DTC
P0ADB
The drive motor generator battery control module compares the contactor control circuit to the drive motor generator battery control modules
internal 12 V measurement reference circuit. This DTC sets when the contactor control circuit voltage is 2 V less than the drive motor generator
battery control module internal voltage reference when the high voltage positive contactor is commanded closed.
P0ADC
The drive motor generator battery control module compares the contactor control circuit to the drive motor generator battery control modules
internal 12 V measurement reference circuit. This DTC sets when the contactor control circuit voltage and the drive motor generator battery control
modules internal voltage reference are within 2 V of each other when the high voltage positive contactor is commanded open.
Action Taken When the DTC Sets
DTCs P0ADB and P0ADC are type C DTCs.
Conditions for Clearing the DTC
DTCs P0ADB and P0ADC are type C DTCs.
Reference Information
Schematic Reference
Hybrid Energy Storage Schematics ()
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views)
Description and Operation
Drive Motor Battery System Description ()
Electrical Information Reference