Saturday, November 16, 2019

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 726

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 726

Moveable Window Schematics (See: Windows and Glass/Windows/Diagrams/Electrical Diagrams)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

Power Windows Description and Operation (See: Windows and Glass/Windows/Description and Operation/Power Windows Description and

Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Circuit/System Verification

Observe the operation of the power windows while commanding each window UP and DOWN by using their respective window switches, each

window should perform the UP and DOWN function.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the appropriate window motor.

2. Connect a test lamp between control circuit terminal A and control circuit terminal B.

3. Ignition ON, command the window UP and DOWN by using the door switch. The test lamp should turn ON when commanding the UP and

DOWN states.

瀚慖f the test lamp is always OFF during either of the commands, test either control circuit for a short to ground or open/high resistance. If

the circuits test normal, replace the door switch.

瀚慖f the test lamp is always ON, test either control circuit for a short to voltage. If the circuits test normal, replace the door switch

4. If all circuits test normal, test or replace the window motor.

Component Testing

Important: When performing the following tests, make sure that the window motor is not all ready in the position the test is attempting to

produce.

1. Ignition OFF, disconnect the harness connector at the appropriate window motor.

2. Install a 25A fused jumper wire between the control terminal A and 12 volts. Momentarily install a jumper wire between the control terminal

B and ground. The window motor should perform the UP or DOWN function.

瀚慖f the function does not perform as specified, replace the window motor.

3. Reverse the jumper wires; the window motor should perform the DOWN or UP function.

瀚慖f the function does not perform as specified, replace the window motor

Repair Instructions

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.

* Front Side Door Window Regulator Motor Replacement (See: Windows and Glass/Windows/Service and Repair/Front Side Door Window

Regulator Motor Replacement)

* Control Module References (See: Testing and Inspection/Programming and Relearning) for DDS and PDS replacement, setup, and

No comments:

Post a Comment