Saturday, August 24, 2019

2020 Subaru Forester P code Page 83

Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms

Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.

Normality Judgment

Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.

Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms

Combination valve changeover pressure diagnosis

Perform the RH combination valve stuck closed diagnosis with the variation of delivery pipe pressure when the RH combination valve turns

closed -> open. Delivery pipe pressure should vary when the RH combination valve turns closed open. When the variation is small,

determine that the RH combination valve is stuck closed.

Abnormality Judgment

If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.

Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms

Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.

Normality Judgment

Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.

Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms

Perform the LH combination valve stuck closed diagnosis with the variation of delivery pipe pressure when the LH combination valve turns

open -> closed.

Delivery pipe pressure should vary when the LH combination valve turns open closed. When the variation is small, determine that the LH

combination valve is stuck closed.

Abnormality Judgment

If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.

Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms

Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.