Time Needed for Diagnosis: 20000 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
NOTE: Initial standard learning value is the value of crank angle initially input at the production plant. And then it will be updated every
time normal judgment has been completed. Learning value will not be updated if NG judgment occurs because timing belt or chain derails
suddenly in process or because wrong assembly occurs during servicing.
Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Time Needed for Diagnosis: Less than 1 second
P0018
DTC P0018 CRANKSHAFT POSITION - CAMSHAFT POSITION CORRELATION (BANK2)
1. OUTLINE OF DIAGNOSIS
Detect the AVCS system malfunction.
Judge as NG when standard timing advance amount is far from learning angle.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITION
4. GENERAL DRIVING CYCLE
Perform the diagnosis continuously after starting engine and while AVCS is not operating.