Abnormality Judgment
Judge as NG when the following conditions are established with diagnosis enable conditions successful.
Time Needed for Diagnosis: 5000 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
Time Needed for Diagnosis: 1000 ms
P2004
DTC P2004 INTAKE MANIFOLD RUNNER CONTROL STUCK OPEN (BANK 1)
1. OUTLINE OF DIAGNOSIS
Detect the malfunction of tumble generator valve motor function.
Judge open fixing malfunction when the opening degree is large even after finishing the tumble generator valve closing driving.
2. ENABLE CONDITION
3. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
4. DIAGNOSTIC METHOD
Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 3000 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Time Needed for Diagnosis: Less than 1 second
P2005
DTC P2005 INTAKE MANIFOLD RUNNER CONTROL STUCK OPEN (BANK 2)
1. OUTLINE OF DIAGNOSIS
Detect the malfunction of tumble generator valve motor function.
Judge open fixing malfunction when the opening degree is large even after finishing the tumble generator valve closing driving.