Tuesday, February 12, 2019

2017 Mercedes Benz S 63 AMG Technical Service Bulletin # 2010020001 Date: 100201

Campaign - Calibrate Front Multicontour Seat Modules
FILE:
SERVICE: GROUP 00 OF SERVICE INFORMATION BINDER
PARTS: GROUP I OF INFORMATION _ PARTS & ACCESSORIES BINDER
Campaign No. 2010020001, February 2010
TO: ALL MERCEDES-BENZ CENTERS
SUBJECT: Model 221, Model Year 2010
Software Calibration Number (SCN) Code - Left and Right Dynamic Multicontour Seat Control Modules
This Service Campaign has been initiated because Daimler AG (DAG), the manufacturer of Mercedes-Benz vehicles, has determined that the
massage function of the front seats may not have been coded to specification in the seat control modules. A Software Calibration Number (SCN)
update to the Left and Right Dynamic Multicontour Seat Control Modules must be installed in the affected vehicles to correct this condition. Dealers
will re-code the Software Calibration Number (SCN) - Dynamic Multicontour Seat Control Modules at the next workshop visit.
Prior to performing this Service Campaign:
^ Please check VMI to determine if the vehicle is involved in the Campaign and if it has been previously repaired.
^ Please review the entire Service Campaign bulletin and follow the repair procedure exactly as described.
Please note that Recall and Service Campaigns do not expire and may also be performed on a vehicle with a vehicle status indicator.
Approximately 63 vehicles are affected.
Procedure
Note:
^ Use DAS/Xentry 11/09 with all associated patches or higher.
^ Follow the steps exactly as described in DAS/Xentry.
^ Connect battery charger (battery voltage >12.5V).

  1. Connect Star Diagnosis.

  2. Perform SCN coding in left dynamic seat (DS) control module:


Control units/Seats and doors/DS - LF left front dynamic seat (Interior CAN bus)/Control unit adaptations/ SCN coding. Follow on-screen
instructions.
3. Perform SCN coding in right dynamic seat (DS) control module:
Control units/Seats and doors/DS - RF right front dynamic seat (Interior CAN bus)/Control unit adaptations/SCN coding. Follow on-screen
instructions.
Note:
The following allowable labor operation should be used when submitting a warranty claim for this repair: