A/C - Fluorescent Dye Leak Testing
Date: September 24, 2007
Order No.: P-B-83.00/97a
Supersedes: P-B-83.00/97 dated May 16, 2007
Group: 83
Revision History
Revision Date Purpose
a 9/24/07 Updated to Include Diagnostic Tree Information
- 5/16/07 Initial issue
SUBJECT:
All Passenger Models
Air Conditioning Not Cooling / Leak Test Using Fluorescent Dye
If you receive customer reports in the above model vehicles of the air conditioning not cooling, temperature fluctuations or noisy compressor
operation, the cause could be low refrigerant level. Refer to the applicable diagnostic tree in the Vehicle Heating, Ventilation, Air Conditioning
(HVAC) Manual found on STAR TekInfo --> EDAC --> Non EDAC Guides. The refrigeration system should be checked for leakage using
fluorescent dye as per the instructions supplied with the leak detection equipment. Please refer to the MBUSA Standard Service Equipment Program
(SSEP) catalog (1-888-458-4040).
Note:
In order to ensure compatibility with all components and materials in the AC system the only approved tracer dye additive to be used is
manufactured by Spectronics Corp. /Tracer Products. If other products are used, warranty submissions could be subject to debit.
2000 Mercedes Benz CLK 320 (208.365) V6-3.2L (112.940) Page 322
Mercedes Benz Diagnostic and Repair Information ,Wiring Diagrams. DTC. TSB. Types: TSB, DTC, Wiring Diagrams, OEM Procedures. Trusted by more than 400,000 technicians. OEM accurate fix for faster repairs. Repair Procedures and Labor Times. Factory Auto Repair info. Request A Demo Today. Factory-Correct Diagrams. Factory Part Numbers. Maintenance Schedules. Repair Procedures. Labor Times. Types: TSB, DTC.Mercedes,Mercedes,Benz,Mercedes-Benz UK,A,Class,B,Class,C,Class,E,Class,CLA,CLS,G,Class,GLA,A
Saturday, February 9, 2019
2005 Mercedes Benz CLK 320 Technical Service Bulletin # P-83_00-97A Date: 070924