- Test terminating resistor of CAN element in control module N3/10 (ME-SFI [ME] control unit).
End of test
1.3.2.2.2. Test terminating resistor of component X63/4 (CAN databus adapter connector, 2-pin).
Test terminating resistor of component X63/4 (CAN databus adapter connector, 2-pin).
Test sequence
- Switch off ignition.
- Connect socket box to component N3/10 (ME-SFI [ME] control unit).
- Disconnect coupling F at component N3/10 (ME-SFI [ME] control unit).
- Measure resistance with multimeter between sockets (F.41) 11 and (F.54) 24 of the 35-pole socket box tester.
Specified value
- Resistor[115...125]ohms
Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Line from component X63/4 (CAN databus adapter connector, 2-pin) to component N3/10 (ME-SFI [ME] control unit)
- Component X63/4 (CAN databus adapter connector, 2-pin)
End of test
1.3.2.2.3. Test terminating resistor of CAN element in control module N3/10 (ME-SFI [ME] control unit).
Test terminating resistor of component N3/10 (ME-SFI [ME] control unit).
Test sequence
- Switch off ignition.
- Connect socket box to component N3/10 (ME-SFI [ME] control unit).
- Connector F is plugged in at control unit.
- Unplug the socket F from the wiring harness at the socket box.
- Measure resistance with multimeter between sockets (F.41) 11 and (F.54) 24 of the 35-pole socket box tester.
Specified value
- Resistor[115...125]ohms
Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Control unit N3/10 (ME-SFI [ME] control unit)
End of test
1.3.3. Test with the aid of the measuring system
Test sequence
- Measurement of level voltage of engine CAN buses CAN bus High and CAN bus Low with the universal oscilloscope
- Separating one user from the connector strip X63/4 (CAN databus adapter connector, 2-pin)
- Observe level voltage.
- Plug in connector again at connector strip X63/4 (CAN databus adapter connector, 2-pin).
- Repeat this procedure for all CAN users.
Specified value
- As soon as the faulty branch was disconnected, the current image of the level voltage changes.
Possible cause of fault in the faulty branch
No comments: