Sunday, July 18, 2021

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 760


- Is the measurement value OK?



YES



The measurement value is OK.End of test



NO



The measurement value is not OK.Possible cause and remedy



- Inspect fuel lines for restriction points (in particular pinching).



- Fuel filter



- Test current consumption of component M3 (Fuel pump).



1.1.3.3. Test current consumption of component M3 (Fuel pump).



Figure legend



- A -ConnectionTest cable 35-pin socket box



- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)



- 05 -35-pin socket box



- 050 -126-pin socket box



- 108 -Test cable 266 589 01 63 00



- N3/10 (ME-SFI [ME] control unit)



- II 1-63ConnectionTest cable



- III 64-126ConnectionTest cable



Warning!



- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).



Continue to test with button F2