2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 1412
Conditions for Running the DTC
* Ignition ON.
* The HVAC control module is ON.
Conditions for Setting the DTC
B393B 04
A PWM greater than 10% is send out but no current is read back.
B393B 0B
Measured current is above threshold of 815 mA.
Action Taken When the DTC Sets
B393B 04
The A/C compressor is disabled.
B393B 0B
* The A/C compressor is disabled.
* Output will be switched off for hardware protection.
Conditions for Clearing the DTC
The condition for setting the DTC is no longer present.
Reference Information
Schematic Reference
HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams)
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views/Connector End Views By Name)
Description and Operation
Automatic HVAC Description and Operation (See: Heating and Air Conditioning/Description and Operation)
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit
Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the Q46 Air Conditioning Compressor Valve.
2. Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 2 and ground.
瀚慖f the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the
FRT HVAC Fuse circuit open, test or replace the Q46 Air Conditioning Compressor Valve.
3. Verify that a test lamp does not illuminate between the B+ circuit terminal 2 and the control circuit terminal 1.
瀚慖f the test lamp illuminates, test the control circuit for a short to ground. If the circuit tests normal, replace the K33 HVAC Control
Module.
4. Remove the test lamp.
5. Command the A/C compressor ON with a scan tool. Verify the scan tool A/C Compressor Refrigerant Solenoid Valve Command parameter