* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions (See: Diagnostic Trouble Code Descriptions/Powertrain Diagnostic Trouble Code

(DTC) Type Definitions)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Special Tools

EN-46999 Displacement On Demand Tester

For equivalent regional tools, refer to Special Tools (See: Powertrain Management/Computers and Control Systems/Tools and Equipment).

Circuit/System Verification

1. Ignition OFF, open the hood to disable the Auto-Stop function. Refer to Hybrid Modes of Operation Description ( See: Hybrid Drive

Systems/Description and Operation/Hybrid Modes of Operation).

2. Ignition ON, verify the scan tool hood position parameter displays Open.

瀚慖f the hood position does not display Open, refer to Diagnostic Trouble Code (DTC) List - Vehicle (See: Diagnostic Trouble Code

Descriptions/Diagnostic Trouble Code (DTC) List - Vehicle) for DTC P254F.

Note: DTC P3401, P3425, P3441, and P3449 sets with an open ignition circuit fuse.

3. Ignition ON, command the appropriate cylinder deactivation solenoid ON and OFF while observing the following status parameters with a

scan tool:

* Cyl. 1, 4, 6, or 7 Deact. Sol. CKT Open Test Status

* Cyl. 1, 4, 6, or 7 Deact. Sol. CKT Short Gnd Test Status

* Cyl. 1, 4, 6, or 7 Deact. Sol. CKT Short Volts Test Status

Each parameter should display OK or Not Run

4. Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the

conditions that you observed from the Freeze Frame/Failure Records data.

Circuit/System Testing

1. Ignition OFF, remove the intake manifold. Refer to Intake Manifold Replacement (See: Engine, Cooling and Exhaust/Engine/Intake

Manifold/Service and Repair).

2. Disconnect the harness connector at the valve lifter oil manifold assembly.

3. Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal E and ground.

瀚慖f the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and

the ignition circuit fuse is open, test all the components connected to the ignition circuit and replace as necessary.

4. Verify that a test lamp does not illuminate between the ignition circuit terminal E and the appropriate cylinder deactivation solenoid control

circuit terminal listed below.

* Cylinder deactivation solenoid valve 1 terminal C

* Cylinder deactivation solenoid valve 2 terminal A

* Cylinder deactivation solenoid valve 3 terminal B

* Cylinder deactivation solenoid valve 4 terminal D

瀚慖f the test lamp illuminates, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM.

5. Remove the test lamp.

6. Command the appropriate cylinder deactivation solenoid ON with a scan tool. Verify the scan tool Cylinder Deactivation Solenoid Valve

Control Circuit High Voltage Test Status parameter displays OK.

瀚慖f not the specified value, test the appropriate control circuit listed below for a short to voltage. If the circuit tests normal, replace the

ECM.

* Cylinder deactivation solenoid valve 1 terminal C

* Cylinder deactivation solenoid valve 2 terminal A

* Cylinder deactivation solenoid valve 3 terminal B

* Cylinder deactivation solenoid valve 4 terminal D